ATS has designed and manufactured a new range of refrigerated compressed air dryers that provide a combination of technology and performance.

FUNCTIONALITY PRINCIPLE
The warm compressed air enters the air/air heat exchanger and becomes pre-cooled by the outgoing cold air. Secondly, the pre-cooled air passes through the evaporator where it is cooled to the required temperature. Thirdly, the condensate, separated from the compressed air in the demister, is discharged automatically by the condensate drain. Finally the refrigerant and the temperature are regulated by a by-pass pressure valve.

Main features
• Low pressure drop
• High technology ultra-compact aluminum heat exchanger
• Easy maintenance
• Oversize components
ULTRA COMPACT HEAT EXCHANGER
The main component of the refrigeration air dryers is the heat exchanger. This compact aluminium unit contains various stages of the treatment of compressed air.
AIR / AIR EXCHANGER
Where the first phase is carried out. In this section the inlet air is pre-cooled and the outlet air is post- heated. This allows the reduction of energy consumption of the chiller circuit and reduces the possibility of condensate forming on the outer surface of the outlet pipe.
FLOW MIXING CHAMBER
Unlike other exchangers on the market, the unit designed has a flow mixing chamber at the air/air exchanger outlet. This passage is very important because the air temperatures at the exit of the air/air exchanger channels are not uniform. The mixing chamber enables the air flow to enter the evaporator channels at a uniform temperature, allowing an optimum exchange.
EVAPORATOR
The air cooled in the evaporator passes through a demister separator which allows the condensate to drain into a large collecting chamber. The design of both module and demister allows pressure drop values to be kept low.
EXCHANGER
EXCHANGER
01. Air/air exchanger
02. Flow mixing chamber
03. Evaporator
04. Demister
CIRCUIT
CIRCUIT
01. Compressor
02. Condensator
03. Fan motor
04. Air/Air heat exchanger
05. Evaporator
06. Condensate discharge valve
07. Capillary tube
08. Dryer filter
09. Demister
10. Ultra compact heat exchanger
11. By-pass valve
OPEN DRYER
OPEN DRYER
01. Controller
02. Fan motor
03. Heat exchanger
04. Condenser
05. Discharge valve
06. Valve strainer
07. Solenoid valve
08. Capillary tube
09. Compressor
10. Hot gas by-pass valve
TECHNICAL DETAILS OF CONTROL PANELS
The control panels are user friendly, allowing the monitor of:
• Dew point
• Operating modes
• Drain management
• Alarm management
CONTROL PANEL TYPE 1
• from DGO24 to DGO780
• from DSI30 to DSI560
CONTROL PANEL TYPE 1
CONTROL PANEL TYPE 2
• from DGO800 to DGO12000
• from DGOW1300 to DGOW 19200
CONTROL PANEL TYPE 2
CONTROL PANEL TYPE 3 touchscreen
• from DPL720 to DPL 6000
CONTROL PANEL TYPE 3 touchscreen